End Suction Pump

DC/DS-Horizontal End Suction Pump

LEADING Horizontal End Suction Pump SUPPLIERS IN CHINA

ViRheos is a professional horizontal end suction pump manufacturer,supplier & exporter with rich industry experience, specializing in the R&D, production and sales of various end suction pumps. Our products feature stable performance, high efficiency and long service life, and are widely exported to global markets, winning high recognition from customers

Economical Pricing Options
Exemplary Quality
Excellent pre-sales and after-sales service
  • Horizontal End Suction Pump
  • Horizontal End Suction Pump
End Suction Pump 1 1

ABOUT DC/DS-HORIZONTAL END SUCTION PUMP  

     The DC and DS series horizontal end suction pumps are single-stage horizontal centrifugal pumps that use centrifugal force from the impeller to transfer liquids. They feature a pull-out design for easy maintenance and are commonly used in HVAC systems and water supply boosting. Key specs include:

  • Temperature Range‌: -15°C to +70°C (normal) or +105°C (hot water)
  • Motor‌: IEC cage-type, IP55 protection, F insulation, 3-phase 220-415V
  • Operating Conditions‌: Clean, non-flammable liquids, ambient ≤40°C, altitude ≤1000m
  • Performance‌: Curves based on ISO 9906, test at 20°C clean water, 2900/1480 rpm.

     They’re ideal for heating, cooling, and water systems requiring reliable, low-maintenance operation.

‌If you need to obtain the detailed performance parameters and drawings, please download the horizontal END SUCTION PUMP PDF

horizontal End Suction Pump for sale

Looking for horizontal end suction pump price ? We offer competitive factory price for end suction pump bulk orders, with detailed specs, performance data and quotation sheets available in our end suction pump PDF—contact us now for customized solutions and instant quotes.

Pump TypePrice Range (USD)Application Scenarios
General End Suction Pump
Basic Model 899 – 7,890Irrigation, water supply, drainage, and other conventional scenarios
Standard Industrial Model260 – 1,000Industrial fluid transfer, cooling systems, etc.
High-Power Model 260 – 1,000High-flow, high-head demand scenarios
Specialized End Suction Pump
Marine/Drainage Pipe Pump3,000 – 7,000Marine, drainage pipes, and other special environments
Fire Pump (Mine Diesel-Driven)3,000 – 9,000Fire protection, mining, and other high-demand scenarios
Chemical Pump (Corrosion-Resistant Fluid Transfer)100 – 2,000Chemical, pharmaceutical, and other corrosion-resistant fluid transfer scenarios
The above prices are for reference only. Please provide parameters for a detailed quotation.

horizontal END SUCTION PUMP application

    Horizontal end suction pumps are widely used in water supply, including water plant filtration, zonal distribution, pipeline pressurization, and high-rise building supply. They also serve industrial pressurization for process water, cleaning systems, and fire protection, as well as liquid transfer in cooling systems, boiler feedwater, and machine tool cooling. Additionally, they handle transfer of oils, acids, and coolants, support water treatment processes like reverse osmosis, and enable irrigation through sprinkler and drip systems.

END SUCTION PUMP APPLICATION
End suction pump applicationSpecific Use Cases
Water SupplyWater plant filtration and distribution, zonal water supply, main pipeline pressurization, high-rise building water supply, hotel pressurization, industrial water supply pressurization
Industrial PressurizationProcess water systems, cleaning systems, high-pressure cleaning systems, fire protection systems, vehicle washing equipment
Industrial Liquid Transfer & CoolingCooling and air conditioning systems, boiler feedwater, condenser systems and cooling towers, machine tool cooling and lubrication packages
Liquid TransferOils and alcohols, acids and alkalis, ethylene glycol and coolants
Water TreatmentUltrafiltration systems, reverse osmosis systems, distillation systems, separators, swimming pools
IrrigationRegional irrigation, sprinkler irrigation, drip irrigation, greenhouse irrigation

horizontal End Suction Pump Installation Diagram

As a professional Chinese end suction pump manufacturer, ViRheos provides detailed technical parameters and horizontal end suction pump installation diagrams in our horizontal end suction pump PDF.

 end suction pump installation diagrams

horizontal End Suction Pump parts

Component NameFunction Description
Pump casingThe pump casing houses the fluid and guides its flow while bearing pressure.
ImpellerThe impeller rotates to generate centrifugal force, propelling the fluid.
Pump coverThe pump cover seals the top of the casing to prevent fluid leakage.
BracketThe bracket supports the pump shaft and stabilizes the pump structure.
Electric motorThe electric motor provides power to rotate the pump shaft.
Pump shaftThe pump shaft connects the motor to the impeller, transmitting power.
Mechanical SealThe mechanical seal prevents fluid leakage from the gap between the shaft and casing.
O-ringThe O-ring seals the connection between the pump cover and casing.
CouplingThe coupling connects the motor shaft to the pump shaft, transmitting torque.
BaseThe base supports the entire pump body, ensuring stable operation.
End Suction Pump part edited

horizontal END SUCTION PUMP factory

As a leading end suction pump manufacturer in China, the end suction pump factory excels in crafting durable stainless steel centrifugal pumps, plant pumps,commercial pump,specifically designed for efficient operations in diverse industrial and agricultural environments.

VIRHEOS

Common Problems and Solutions for horizontal End Suction Pump

What’s the difference between an end suction pump and double suction pump?

End suction pumps have one impeller inlet; double suction pumps have two, for larger flows and less axial force.

Close coupled vs base mounted end suction pump—which is better?

Close coupled saves space; base mounted offers higher stability for heavy-duty industrial use.

Can an end suction fire pump work as a water suction pump?

Yes, but it’s not cost-effective—fire pumps are built for emergency high-pressure, not continuous routine use.

What’s a horizontal end suction centrifugal pump used for?

HVAC systems, industrial water circulation, irrigation, and building water supply.

Where to get an end suction pump pdf?

Download from official end suction pump manufacturer, supplier & exporter websites, or request via their sales teams.

Is an electric water suction pump a type of suction pump?

Yes—it’s an electric-powered suction pump designed specifically for clean water transfer.

What’s the main end suction pump application in industry?

Boiler feed, cooling tower circulation, process fluid transfer, and wastewater pre-treatment.

How to pick a suction pump for sewage?

Choose anti-clog impellers, corrosion-resistant materials, and match flow/head to sewage solid particle size.

Where to find end suction pumps for sale globally?

From certified end suction pump manufacturers, suppliers & exporters with ISO/CE/FM approvals and global shipping.

Drainage suction pump vs water suction pump—what’s the difference?

Drainage pumps handle dirty water/sediment; water suction pumps are for clean water transfer only.

Leave Your Message
Request for detailed specifications and quotation
滚动至顶部